Two CANbus Ports
The high-performance, 32-bit, 800 MHz processor and the memory capacity of 2 GB of RAM plus 256 MB of DDR2 make the OPUS A6s a powerful heavyweight.
Fitted with two CANbus ports, it leaves no wish unfulfi lled. A front-mounted, high-speed USB port and three camera inputs can also be included as optional extras. Problem-free functionality is assured by.
Code 113 PUS A6 SB 7 G2 CFG STD
Code 113 DISPLAY OPUS A6 STANDARD BASIC 7 NEUTRAL ANTI-FOG CFG STD
Code 1141204001800 DISPLAY OPUS A6 STANDARD BASIC 7 NEUTRAL CODESYS
Code 1141206001400 DISPLAY OPUS A6 STANDARD BASIC 7 NEUTRAL ISO-VT
Categoria: Displays (safety/non safety) Tag: Topcon Electronics, Automation, Display
Tractor, Barca, Motostivuitor
Hardware
Processor Freescale I.MX6 , solo 800 MHz
Mass storage 2GByte
RAM 256 Mbyte
RTC Buffered by gold cup
Temperature range Operating: -30..+65 C Storage: -40..+85 C
Electrical
Display TFT Color Graphic LCD with LED backlight
Resolution 800 x 480 px (WVGA), 15:9
Colors 262k
Brightness typ. 400 cd/m
Contrast Ratio typ. 500:1
Size 7 , 152 mm (W) x 91 mm (H)
Indicators and sensors Light sensor
1 Multicolor-LED
2 Status-LED s
Power requirements 9 36 V DC Short circuit protection.
Overvoltage resistance 48 V for max. 2 minutes.
Inverse polarity protection up to -48 V DC
Interfaces
CAN bus 2 x CAN-Interfaces according to ISO 1 1898 CAN specification 2.0 B active,
up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s)
RS 232 1 x RS232-Interface Type: EIA232 (only RxD, TxD, GND), Speed: max. 115 Kbps
USB HOST 2.0 Main connector: 1 x Full speed
Ethernet 1 x 10/100 Mbit/s Base T
Buzzer Yes 80 dB @ 1kHz in 1 m distance
Connectors
Main T yco-AMP 1437288-6 Mating connector (customer) T yco-AMP 3-1437290-7
Mating crimp contact (customer) T yco-AMP 3-1447221-4
Video M12 round connecto r , female, 5-pole, B-coded, acc. to EN 61076-2-101
Ethernet M12 round connecto r , female, 4-pole, D-coded acc. to EN 61076-2-101
Software
Operating System Linux 2.6.28
Application Programming Motronica M- V ision OPUS Projektor Optional: Codesys-Tools (3.5)
Optional: ISO-VT Optional: C/C++
Testing and verification
CE-Compliance EU Directive 2014/30/EU (EMC) according to
EN 12895: Industrial Trucks Electromagnetic compatibility
EN 13309: Construction machinery Electromagnetic compatibility of machines with internal electrical power supply
EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria
E1 - Type approval EU Directive ECE R 10.4
Protection Level (IP Code) IP 65 and IP 66 according to ISO 20653: Road Vehicles
Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access
Electrical 12 and 24 V -Systems according to ISO 16750-2: Road V ehicles Environmental conditions and testing for electrical and electronic equipment Electrical loads ISO 15003: Agricultural Engineering Electrical and electronic equipment T esting resistance to environmental conditions
Mechanical ISO 16750-3: Road V ehicles Environmental
conditions and testing for electrical and electronic equipment Mechanical loads, Code L
ISO 15003: Agricultural Engineering Electrical and electronic equipment T esting resistance to environmental conditions
Mechanical Shock: Level 2
Random V ibration: Level 2
Sinusoidal V ibration: Level 2
Climate ISO 16750-4: Road V ehicles Environmental conditions and testing for electrical and electronic equipment Climatic Loads
Operating T emperature Range: -30 +65 C
Storage T emperature Range: -40 +85 C
ISO 15003: Agricultural Engineering Electrical and electronic equipment T esting resistance to environmental conditions Publi24_1685102000