controler 6-60V, 30A, incarcare automatizare baterii lithium ... plumb
Specificații
Descriere
Controler 6-60V, 30A incarcare automatizare baterii
Acest modul este controler incarcare baterii, se poate seta parametri de incarcare la ce tensiune se doreste, decuplarea automata dupa incarcare. Foarte bine in cazul bateriilor lithiu. Decuplare automata peste un timp prestabilit, daca o baterie are o problema nu trebuie sa stea la incarcat mai mult decat ar fi in mod normal.
Specificatii:
- alimentare: 6-60V
- plaja de lucru 6-60V
- curent max: 30A
- schema de conectare in poze
Setare rapida parametri (fara timer):
- Se apasa 2 sec pe SETUP apoi apare un meniu (blink)
- apasarea scurta pe SETUP (click) navigare prin meniu
- dupa selectie meniu Setare prag de sus (up), se alege tensiunea dorita din sageti UP DOWN
- dupa selectie meniu Setare prag de jos (dn), se alege tensiunea dorita din sageti UP DOWN
- apoi salvarea se face apasand SETUP 2 sec si gata
Nota: pentru curenti mai mari de 30A ... se foloseste releul de pe placa spre a comanda alt releu mai puternic.
Specificatiile originale ale manualului:
1.Module Highlights:
1. Support Lead-acid battery and Acting Battery,voltage range:6V 60V;
2. Can display voltage,percent of battery,charging time at the same time through LCD;
3. The function is very powerful,realizes the automatic charge control,
the control charge time, also may set up and uploads the corresponding parameter through the serial port;
2.Function description
1) Automatic Charge control function:
By setting the volt-HI: UP volt-LI: dn ;When the battery voltage is below the volt-LI: dn ,the relay leads,the charger begins to charge the battery;when the battery voltage is up to volt-HI: UP ,the relay is diconnected and the automatic charge is completed once;
2) Charge Time Control Function:
How to turn on the time control function?
After entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is: - - : - - h, the default does not turn on time control function;
After the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI dn , the charger began to charge the battery, the system began to clock; During the timing, the battery voltage = volt-HI UP , relay disconnect; If the OP time is up, the battery voltage is still the lower volt-LI dn , the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Press any key to stop flashing;
Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours. dumploader